Show filters
84 Total Results
Displaying 71-80 of 84
Sort by:
Attacker Value
Unknown

CVE-2014-0777

Disclosure Date: April 11, 2014 (last updated October 05, 2023)
The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service (out-of-bounds read and daemon crash) via a crafted packet.
0
Attacker Value
Unknown

CVE-2014-0789

Disclosure Date: April 04, 2014 (last updated October 05, 2023)
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.
0
Attacker Value
Unknown

CVE-2013-0662

Disclosure Date: April 01, 2014 (last updated October 05, 2023)
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
0
Attacker Value
Unknown

CVE-2014-0774

Disclosure Date: February 28, 2014 (last updated October 05, 2023)
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
0
Attacker Value
Unknown

CVE-2013-2829

Disclosure Date: February 14, 2014 (last updated October 05, 2023)
MatrikonOPC SCADA DNP3 OPC Server 1.2.2.0 and earlier allows remote attackers to cause a denial of service (infinite loop) via a malformed DNP3 packet.
0
Attacker Value
Unknown

CVE-2013-2814

Disclosure Date: December 17, 2013 (last updated October 05, 2023)
Cooper Power Systems Cybectec DNP3 Master OPC Server allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors.
0
Attacker Value
Unknown

CVE-2013-2791

Disclosure Date: September 09, 2013 (last updated October 05, 2023)
MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service (master-station daemon crash) via a malformed DNP3 TCP packet from the IP address of an outstation.
0
Attacker Value
Unknown

CVE-2012-1801

Disclosure Date: April 18, 2012 (last updated October 04, 2023)
Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote attackers to execute arbitrary code via crafted input data.
0
Attacker Value
Unknown

CVE-2012-0245

Disclosure Date: March 09, 2012 (last updated October 04, 2023)
Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.
0
Attacker Value
Unknown

CVE-2011-1914

Disclosure Date: February 21, 2012 (last updated October 04, 2023)
Buffer overflow in the Advantech ADAM OLE for Process Control (OPC) Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors.
0