Show filters
56 Total Results
Displaying 51-56 of 56
Sort by:
Attacker Value
Unknown

CVE-2019-19441

Disclosure Date: August 07, 2019 (last updated November 27, 2024)
HUAWEI P30 smart phones with versions earlier than 10.0.0.166(C00E66R1P11) have an information leak vulnerability. An attacker could send specific command in the local area network (LAN) to exploit this vulnerability. Successful exploitation may cause information leak.
Attacker Value
Unknown

CVE-2019-5215

Disclosure Date: June 04, 2019 (last updated November 27, 2024)
There is a man-in-the-middle (MITM) vulnerability on Huawei P30 smartphones versions before ELE-AL00 9.1.0.162(C01E160R1P12/C01E160R2P1), and P30 Pro versions before VOG-AL00 9.1.0.162 (C01E160R1P12/C01E160R2P1). When users establish connection and transfer data through Huawei Share, an attacker could sniff, spoof and do a series of operations to intrude the Huawei Share connection and launch a man-in-the-middle attack to obtain and tamper the data. (Vulnerability ID: HWPSIRT-2019-03109)
0
Attacker Value
Unknown

CVE-2019-5307

Disclosure Date: June 04, 2019 (last updated November 27, 2024)
Some Huawei 4G LTE devices, P30 versions before ELE-AL00 9.1.0.162(C01E160R1P12/C01E160R2P1) and P30 Pro versions before VOG-AL00 9.1.0.162(C01E160R1P12/C01E160R2P1), are exposed to a message replay vulnerability. For the sake of better compatibility, these devices implement a less strict check on the NAS message sequence number (SN), specifically NAS COUNT. As a result, an attacker can construct a rogue base station and replay the GUTI reallocation command message in certain conditions to tamper with GUTIs, or replay the Identity request message to obtain IMSIs. (Vulnerability ID: HWPSIRT-2019-04107)
0
Attacker Value
Unknown

CVE-2018-10597

Disclosure Date: June 05, 2018 (last updated November 26, 2024)
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
Attacker Value
Unknown

CVE-2018-10601

Disclosure Date: June 05, 2018 (last updated November 26, 2024)
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
Attacker Value
Unknown

CVE-2018-10599

Disclosure Date: June 05, 2018 (last updated November 26, 2024)
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
0