Show filters
85 Total Results
Displaying 51-60 of 85
Sort by:
Attacker Value
Unknown
CVE-2018-9328
Disclosure Date: April 05, 2018 (last updated November 26, 2024)
PHP Scripts Mall Redbus Clone Script 3.0.6 has XSS via the ter_from or tag parameter to results.php.
0
Attacker Value
Unknown
CVE-2018-4840
Disclosure Date: March 08, 2018 (last updated November 26, 2024)
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
0
Attacker Value
Unknown
CVE-2018-4838
Disclosure Date: March 08, 2018 (last updated November 26, 2024)
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
0
Attacker Value
Unknown
CVE-2018-4839
Disclosure Date: March 08, 2018 (last updated November 26, 2024)
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
0
Attacker Value
Unknown
CVE-2017-6032
Disclosure Date: June 30, 2017 (last updated November 26, 2024)
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.
0
Attacker Value
Unknown
CVE-2017-6034
Disclosure Date: June 30, 2017 (last updated November 26, 2024)
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
0
Attacker Value
Unknown
CVE-2015-0245
Disclosure Date: February 13, 2015 (last updated December 28, 2023)
D-Bus 1.4.x through 1.6.x before 1.6.30, 1.8.x before 1.8.16, and 1.9.x before 1.9.10 does not validate the source of ActivationFailure signals, which allows local users to cause a denial of service (activation failure error returned) by leveraging a race condition involving sending an ActivationFailure signal before systemd responds.
0
Attacker Value
Unknown
CVE-2014-7824
Disclosure Date: November 18, 2014 (last updated December 28, 2023)
D-Bus 1.3.0 through 1.6.x before 1.6.26, 1.8.x before 1.8.10, and 1.9.x before 1.9.2 allows local users to cause a denial of service (prevention of new connections and connection drop) by queuing the maximum number of file descriptors. NOTE: this vulnerability exists because of an incomplete fix for CVE-2014-3636.1.
0
Attacker Value
Unknown
CVE-2014-3636
Disclosure Date: October 25, 2014 (last updated December 28, 2023)
D-Bus 1.3.0 through 1.6.x before 1.6.24 and 1.8.x before 1.8.8 allows local users to (1) cause a denial of service (prevention of new connections and connection drop) by queuing the maximum number of file descriptors or (2) cause a denial of service (disconnect) via multiple messages that combine to have more than the allowed number of file descriptors for a single sendmsg call.
0
Attacker Value
Unknown
CVE-2014-3638
Disclosure Date: September 22, 2014 (last updated December 28, 2023)
The bus_connections_check_reply function in config-parser.c in D-Bus before 1.6.24 and 1.8.x before 1.8.8 allows local users to cause a denial of service (CPU consumption) via a large number of method calls.
0