Show filters
74 Total Results
Displaying 41-50 of 74
Sort by:
Attacker Value
Unknown

CVE-2018-7231

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.
Attacker Value
Unknown

CVE-2018-7230

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67.
Attacker Value
Unknown

CVE-2018-7232

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
Attacker Value
Unknown

CVE-2018-7236

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.
Attacker Value
Unknown

CVE-2018-7229

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
Attacker Value
Unknown

CVE-2018-7233

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.
Attacker Value
Unknown

CVE-2018-7238

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.
Attacker Value
Unknown

CVE-2018-7237

Disclosure Date: March 09, 2018 (last updated November 26, 2024)
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'
Attacker Value
Unknown

CVE-2017-14484

Disclosure Date: September 15, 2017 (last updated November 26, 2024)
The Gentoo sci-mathematics/gimps package before 28.10-r1 for Great Internet Mersenne Prime Search (GIMPS) allows local users to gain privileges by creating a hard link under /var/lib/gimps, because an unsafe "chown -R" command is executed.
0
Attacker Value
Unknown

CVE-2017-7967

Disclosure Date: May 09, 2017 (last updated November 26, 2024)
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
0