Show filters
86 Total Results
Displaying 41-50 of 86
Sort by:
Attacker Value
Unknown

CVE-2018-7112

Disclosure Date: December 03, 2018 (last updated November 27, 2024)
The HPE-provided Windows firmware installer for certain Gen9, Gen8, G7,and G6 HPE servers allows local disclosure of privileged information. This issue was resolved in previously provided firmware updates as follows. The HPE Windows firmware installer was updated in the system ROM updates which also addressed the original Spectre/Meltdown set of vulnerabilities. At that time, the Windows firmware installer was also updated in the versions of HPE Integrated Lights-Out 2, 3, and 4 (iLO 2, 3, and 4) listed in the security bulletin. The updated HPE Windows firmware installer was released in the system ROM and HPE Integrated Lights-Out (iLO) releases documented in earlier HPE Security Bulletins: HPESBHF03805, HPESBHF03835, HPESBHF03831. Windows-based systems that have already been updated to the system ROM or iLO versions described in these security bulletins require no further action.
0
Attacker Value
Unknown

CVE-2018-7101

Disclosure Date: September 27, 2018 (last updated November 27, 2024)
A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30.
0
Attacker Value
Unknown

CVE-2018-7105

Disclosure Date: September 27, 2018 (last updated November 27, 2024)
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information.
0
Attacker Value
Unknown

CVE-2018-7093

Disclosure Date: August 14, 2018 (last updated November 27, 2024)
A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service.
0
Attacker Value
Unknown

CVE-2016-4406

Disclosure Date: August 06, 2018 (last updated November 27, 2024)
A remote cross site scripting vulnerability was identified in HPE iLO 3 all version prior to v1.88 and HPE iLO 4 all versions prior to v2.44.
0
Attacker Value
Unknown

CVE-2017-8987

Disclosure Date: August 06, 2018 (last updated November 27, 2024)
A Unauthenticated Remote Denial of Service vulnerability was identified in HPE Integrated Lights-Out 3 (iLO 3) version v1.88 only. The vulnerability is resolved in iLO3 v1.89 or subsequent versions.
0
Attacker Value
Unknown

CVE-2018-7078

Disclosure Date: August 06, 2018 (last updated November 27, 2024)
A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30.
0
Attacker Value
Unknown

CVE-2017-8979

Disclosure Date: February 15, 2018 (last updated November 26, 2024)
Security vulnerabilities in the HPE Integrated Lights-Out 2 (iLO 2) firmware could be exploited remotely to allow authentication bypass, code execution, and denial of service.
0
Attacker Value
Unknown

CVE-2017-12543

Disclosure Date: February 15, 2018 (last updated November 26, 2024)
A remote disclosure of information vulnerability in Moonshot Remote Console Administrator Prior to 2.50, iLO4 prior to v2.53, iLO3 prior to v1.89 and iLO2 prior to v2.30 was found.
0
Attacker Value
Unknown

CVE-2018-2566

Disclosure Date: January 18, 2018 (last updated November 26, 2024)
Vulnerability in the Integrated Lights Out Manager (ILOM) component of Oracle Sun Systems Products Suite (subcomponent: Remote Console Application). Supported versions that are affected are 3.x and 4.x. Difficult to exploit vulnerability allows low privileged attacker with network access via TLS to compromise Integrated Lights Out Manager (ILOM). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Integrated Lights Out Manager (ILOM), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Integrated Lights Out Manager (ILOM) accessible data as well as unauthorized access to critical data or complete access to all Integrated Lights Out Manager (ILOM) accessible data. CVSS 3.0 Base Score 7.7 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N).
0