Show filters
52 Total Results
Displaying 41-50 of 52
Sort by:
Attacker Value
Unknown

CVE-2019-10041

Disclosure Date: March 25, 2019 (last updated November 27, 2024)
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/form2userconfig.cgi to edit the system account without authentication.
0
Attacker Value
Unknown

CVE-2019-10040

Disclosure Date: March 25, 2019 (last updated November 27, 2024)
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication.
0
Attacker Value
Unknown

CVE-2019-10042

Disclosure Date: March 25, 2019 (last updated November 27, 2024)
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/LoadDefaultSettings to reset the router without authentication.
0
Attacker Value
Unknown

CVE-2019-10039

Disclosure Date: March 25, 2019 (last updated November 27, 2024)
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication.
0
Attacker Value
Unknown

CVE-2018-20305

Disclosure Date: December 20, 2018 (last updated November 27, 2024)
D-Link DIR-816 A2 1.10 B05 devices allow arbitrary remote code execution without authentication via the newpass parameter. In the /goform/form2userconfig.cgi handler function, a long password may lead to a stack-based buffer overflow and overwrite a return address.
0
Attacker Value
Unknown

CVE-2018-17068

Disclosure Date: September 15, 2018 (last updated November 27, 2024)
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction in the handler function of the /goform/Diagnosis route. This could lead to command injection via shell metacharacters in the sendNum parameter.
0
Attacker Value
Unknown

CVE-2018-17065

Disclosure Date: September 15, 2018 (last updated November 27, 2024)
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. Within the handler function of the /goform/DDNS route, a very long password could lead to a stack-based buffer overflow and overwrite the return address.
0
Attacker Value
Unknown

CVE-2018-17067

Disclosure Date: September 15, 2018 (last updated November 27, 2024)
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. A very long password to /goform/formLogin could lead to a stack-based buffer overflow and overwrite the return address.
0
Attacker Value
Unknown

CVE-2018-17066

Disclosure Date: September 15, 2018 (last updated November 27, 2024)
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction in the handler function of the /goform/form2systime.cgi route. This could lead to command injection via shell metacharacters in the datetime parameter.
0
Attacker Value
Unknown

CVE-2018-17064

Disclosure Date: September 15, 2018 (last updated November 27, 2024)
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.
0