Show filters
41 Total Results
Displaying 31-40 of 41
Sort by:
Attacker Value
Unknown

CVE-2012-2515

Disclosure Date: July 05, 2012 (last updated October 04, 2023)
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
0
Attacker Value
Unknown

CVE-2012-2516

Disclosure Date: July 05, 2012 (last updated October 04, 2023)
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a "command injection vulnerability."
0
Attacker Value
Unknown

CVE-2012-0229

Disclosure Date: March 15, 2012 (last updated October 04, 2023)
The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted session on TCP port 14000 to (1) ihDataArchiver.exe or (2) ihDataArchiver_x64.exe.
0
Attacker Value
Unknown

CVE-2012-0232

Disclosure Date: March 15, 2012 (last updated October 04, 2023)
Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6, 3.0, 3.0 SP1, and 3.5 allows remote attackers to modify the configuration via crafted strings.
0
Attacker Value
Unknown

CVE-2012-0230

Disclosure Date: March 15, 2012 (last updated October 04, 2023)
PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12299.
0
Attacker Value
Unknown

CVE-2012-0231

Disclosure Date: March 15, 2012 (last updated October 04, 2023)
PRLicenseMgr.exe in the Proficy Server License Manager in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12401.
0
Attacker Value
Unknown

CVE-2011-1919

Disclosure Date: November 02, 2011 (last updated October 04, 2023)
Multiple stack-based buffer overflows in GE Intelligent Platforms Proficy Applications before 4.4.1 SIM 101 and 5.x before 5.0 SIM 43 allow remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via crafted TCP message traffic to (1) PRProficyMgr.exe in Proficy Server Manager, (2) PRGateway.exe in Proficy Server Gateway, (3) PRRDS.exe in Proficy Remote Data Service, or (4) PRLicenseMgr.exe in Proficy Server License Manager.
0
Attacker Value
Unknown

CVE-2011-1918

Disclosure Date: November 02, 2011 (last updated October 04, 2023)
Stack-based buffer overflow in the Data Archiver service in GE Intelligent Platforms Proficy Historian before 3.5 SIM 17 and 4.x before 4.0 SIM 12 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via crafted TCP message traffic.
0
Attacker Value
Unknown

CVE-2011-3320

Disclosure Date: November 02, 2011 (last updated October 04, 2023)
Cross-site scripting (XSS) vulnerability in the Web Administrator component in GE Intelligent Platforms Proficy Historian 4.x and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified parameters.
0
Attacker Value
Unknown

CVE-2008-0174

Disclosure Date: January 29, 2008 (last updated February 15, 2024)
GE Fanuc Proficy Real-Time Information Portal 2.6 and earlier uses HTTP Basic Authentication, which transmits usernames and passwords in base64-encoded cleartext and allows remote attackers to steal the passwords and gain privileges.