Show filters
40 Total Results
Displaying 31-40 of 40
Sort by:
Attacker Value
Unknown
CVE-2021-0225
Disclosure Date: April 14, 2021 (last updated February 22, 2025)
An Improper Check for Unusual or Exceptional Conditions in Juniper Networks Junos OS Evolved may cause the stateless firewall filter configuration which uses the action 'policer' in certain combinations with other options to not take effect. An administrator can use the following CLI command to see the failures with filter configuration: user@device> show log kfirewall-agent.log | match ERROR Jul 23 14:16:03 ERROR: filter not supported This issue affects Juniper Networks Junos OS Evolved: Versions 19.1R1-EVO and above prior to 20.3R1-S2-EVO, 20.3R2-EVO. This issue does not affect Juniper Networks Junos OS.
0
Attacker Value
Unknown
CVE-2021-0259
Disclosure Date: April 14, 2021 (last updated February 22, 2025)
Due to a vulnerability in DDoS protection in Juniper Networks Junos OS and Junos OS Evolved on QFX5K Series switches in a VXLAN configuration, instability might be experienced in the underlay network as a consequence of exceeding the default ddos-protection aggregate threshold. If an attacker on a client device on the overlay network sends a high volume of specific, legitimate traffic in the overlay network, due to an improperly detected DDoS violation, the leaf might not process certain L2 traffic, sent by spines in the underlay network. Continued receipt and processing of the high volume traffic will sustain the Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on QFX5K Series: 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R2-S8, 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 v…
0
Attacker Value
Unknown
CVE-2021-0236
Disclosure Date: April 14, 2021 (last updated February 22, 2025)
Due to an improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved the Routing Protocol Daemon (RPD) service, upon receipt of a specific matching BGP packet meeting a specific term in the flowspec configuration, crashes and restarts causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects only Multiprotocol BGP (MP-BGP) VPNv6 FlowSpec deployments. This issue affects: Juniper Networks Junos OS: 18.4 versions prior to 18.4R1-S8, 18.4R2-S7, 18.4R3-S7; 19.1 versions prior to 19.1R2-S2, 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S1, 20.3R2. Juniper Networks Junos OS Evolved: All versions after 18.4R1-EVO prior to 20.3R2-EVO. This issue does not a…
0
Attacker Value
Unknown
CVE-2021-0264
Disclosure Date: April 14, 2021 (last updated February 22, 2025)
A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bullet…
0
Attacker Value
Unknown
CVE-2021-0208
Disclosure Date: January 13, 2021 (last updated February 22, 2025)
An improper input validation vulnerability in the Routing Protocol Daemon (RPD) service of Juniper Networks Junos OS allows an attacker to send a malformed RSVP packet when bidirectional LSPs are in use, which when received by an egress router crashes the RPD causing a Denial of Service (DoS) condition. Continued receipt of the packet will sustain the Denial of Service. This issue affects: Juniper Networks Junos OS: All versions prior to 17.3R3-S10 except 15.1X49-D240 for SRX series; 17.4 versions prior to 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.3 versions prior to 18.3R3-S2; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R3-S3; 19.2 versions prior to 19.2R3; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R2-S2, 19.4R3-S1; 20.1 versions prior to 20.1R1-S4, 20.1R2; 15.1X49 versions prior to 15.1X49-D240 on SRX Series. Juniper Networks Junos OS Evolved: 19.3 version…
0
Attacker Value
Unknown
CVE-2021-0211
Disclosure Date: January 13, 2021 (last updated February 22, 2025)
An improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved Routing Protocol Daemon (RPD) service allows an attacker to send a valid BGP FlowSpec message thereby causing an unexpected change in the route advertisements within the BGP FlowSpec domain leading to disruptions in network traffic causing a Denial of Service (DoS) condition. Continued receipt of these update messages will cause a sustained Denial of Service condition. This issue affects Juniper Networks: Junos OS: All versions prior to 17.3R3-S10 with the exceptions of 15.1X49-D240 on SRX Series and 15.1R7-S8 on EX Series; 17.3 versions prior to 17.3R3-S10; 17.4 versions prior to 17.4R2-S12, 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R2-S8, 18.2R3-S6; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R1-S8, 18.4R2-S6, 18.4R3-S6; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3-S3; 19.2 versions prior to 19.2R3-S1; 19.3 versions prior to…
0
Attacker Value
Unknown
CVE-2020-1681
Disclosure Date: October 14, 2020 (last updated February 22, 2025)
Receipt of a specifically malformed NDP packet sent from the local area network (LAN) to a device running Juniper Networks Junos OS Evolved can cause the ndp process to crash, resulting in a Denial of Service (DoS). The process automatically restarts without intervention, but a continuous receipt of the malformed NDP packets could leaded to an extended Denial of Service condition. During this time, IPv6 neighbor learning will be affected. The issue occurs when parsing the incoming malformed NDP packet. Rather than simply discarding the packet, the process asserts, performing a controlled exit and restart, thereby avoiding any chance of an unhandled exception. Exploitation of this vulnerability is limited to a temporary denial of service, and cannot be leveraged to cause additional impact on the system. This issue is limited to the processing of IPv6 NDP packets. IPv4 packet processing cannot trigger, and is unaffected by this vulnerability. This issue affects all Juniper Networks Juno…
0
Attacker Value
Unknown
CVE-2020-1666
Disclosure Date: October 14, 2020 (last updated February 22, 2025)
The system console configuration option 'log-out-on-disconnect' In Juniper Networks Junos OS Evolved fails to log out an active CLI session when the console cable is disconnected. This could allow a malicious attacker with physical access to the console the ability to resume a previous interactive session and possibly gain administrative privileges. This issue affects all Juniper Networks Junos OS Evolved versions after 18.4R1-EVO, prior to 20.2R1-EVO.
0
Attacker Value
Unknown
CVE-2020-1644
Disclosure Date: July 08, 2020 (last updated February 21, 2025)
On Juniper Networks Junos OS and Junos OS Evolved devices, the receipt of a specific BGP UPDATE packet causes an internal counter to be incremented incorrectly, which over time can lead to the routing protocols process (RPD) crash and restart. This issue affects both IBGP and EBGP multihop deployment in IPv4 or IPv6 network. This issue affects: Juniper Networks Junos OS: 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.2X75 versions prior to 18.2X75-D13, 18.2X75-D411.1, 18.2X75-D420.18, 18.2X75-D52.3, 18.2X75-D60; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Juniper Networks Junos OS Evolved: any rel…
0
Attacker Value
Unknown
CVE-2020-1638
Disclosure Date: April 08, 2020 (last updated February 21, 2025)
The FPC (Flexible PIC Concentrator) of Juniper Networks Junos OS and Junos OS Evolved may restart after processing a specific IPv4 packet. Only packets destined to the device itself, successfully reaching the RE through existing edge and control plane filtering, will be able to cause the FPC restart. When this issue occurs, all traffic via the FPC will be dropped. By continuously sending this specific IPv4 packet, an attacker can repeatedly crash the FPC, causing an extended Denial of Service (DoS) condition. This issue can only occur when processing a specific IPv4 packet. IPv6 packets cannot trigger this issue. This issue affects: Juniper Networks Junos OS on MX Series with MPC10E or MPC11E and PTX10001: 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. Juniper Networks Junos OS Evolved on on QFX5220, and PTX10003 series: 19.2-EVO versions; 19.3-EVO versions; 19.4-EVO versions prior to 19.4R2-EVO. This issue…
0