Show filters
30 Total Results
Displaying 21-30 of 30
Sort by:
Attacker Value
Unknown
CVE-2020-6962
Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
0
Attacker Value
Unknown
CVE-2020-6961
Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
0
Attacker Value
Unknown
CVE-2020-6964
Disclosure Date: January 24, 2020 (last updated February 21, 2025)
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
0
Attacker Value
Unknown
CVE-2016-2274
Disclosure Date: February 13, 2017 (last updated November 26, 2024)
An issue was discovered in Adcon Telemetry A850 Telemetry Gateway Base Station. The Web Interface does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output; this could allow for cross-site scripting.
0
Attacker Value
Unknown
CVE-2015-7932
Disclosure Date: December 24, 2015 (last updated November 25, 2024)
Adcon Telemetry A840 Telemetry Gateway Base Station allows remote attackers to obtain sensitive information by sniffing the network.
0
Attacker Value
Unknown
CVE-2015-7934
Disclosure Date: December 24, 2015 (last updated November 25, 2024)
The Java client in Adcon Telemetry A840 Telemetry Gateway Base Station allows remote attackers to discover log-file pathnames via unspecified vectors.
0
Attacker Value
Unknown
CVE-2015-7930
Disclosure Date: December 24, 2015 (last updated November 25, 2024)
Adcon Telemetry A840 Telemetry Gateway Base Station has hardcoded credentials, which allows remote attackers to obtain administrative access via unspecified vectors.
0
Attacker Value
Unknown
CVE-2015-7931
Disclosure Date: December 24, 2015 (last updated November 25, 2024)
The Java client in Adcon Telemetry A840 Telemetry Gateway Base Station does not authenticate the station device, which allows man-in-the-middle attackers to spoof devices and obtain sensitive information by reading cleartext packet data, related to the lack of SSL support.
0
Attacker Value
Unknown
CVE-2015-7910
Disclosure Date: November 19, 2015 (last updated October 05, 2023)
Exemys Telemetry Web Server relies on an HTTP Location header to indicate that a client is unauthorized, which allows remote attackers to bypass intended access restrictions by disregarding this header and processing the response body.
0
Attacker Value
Unknown
CVE-2014-4615
Disclosure Date: August 19, 2014 (last updated October 05, 2023)
The notifier middleware in OpenStack PyCADF 0.5.0 and earlier, Telemetry (Ceilometer) 2013.2 before 2013.2.4 and 2014.x before 2014.1.2, Neutron 2014.x before 2014.1.2 and Juno before Juno-2, and Oslo allows remote authenticated users to obtain X_AUTH_TOKEN values by reading the message queue (v2/meters/http.request).
0