Show filters
31 Total Results
Displaying 21-30 of 31
Sort by:
Attacker Value
Unknown
CVE-2014-2909
Disclosure Date: April 25, 2014 (last updated October 05, 2023)
CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors.
0
Attacker Value
Unknown
CVE-2014-2908
Disclosure Date: April 25, 2014 (last updated October 05, 2023)
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
0
Attacker Value
Unknown
CVE-2014-2250
Disclosure Date: March 24, 2014 (last updated October 05, 2023)
The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than CVE-2014-2251.
0
Attacker Value
Unknown
CVE-2014-2252
Disclosure Date: March 24, 2014 (last updated October 05, 2023)
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted PROFINET packets, a different vulnerability than CVE-2014-2253.
0
Attacker Value
Unknown
CVE-2014-2254
Disclosure Date: March 24, 2014 (last updated October 05, 2023)
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets, a different vulnerability than CVE-2014-2255.
0
Attacker Value
Unknown
CVE-2014-2256
Disclosure Date: March 24, 2014 (last updated October 05, 2023)
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257.
0
Attacker Value
Unknown
CVE-2014-2258
Disclosure Date: March 24, 2014 (last updated October 05, 2023)
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets, a different vulnerability than CVE-2014-2259.
0
Attacker Value
Unknown
CVE-2013-0700
Disclosure Date: April 22, 2013 (last updated October 05, 2023)
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
0
Attacker Value
Unknown
CVE-2013-2780
Disclosure Date: April 22, 2013 (last updated October 05, 2023)
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
0
Attacker Value
Unknown
CVE-2012-3040
Disclosure Date: October 10, 2012 (last updated October 05, 2023)
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
0