Show filters
32 Total Results
Displaying 21-30 of 32
Sort by:
Attacker Value
Unknown

CVE-2019-6855

Disclosure Date: January 06, 2020 (last updated February 21, 2025)
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
Attacker Value
Unknown

CVE-2015-6462

Disclosure Date: March 21, 2019 (last updated April 11, 2024)
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.
0
Attacker Value
Unknown

CVE-2015-6461

Disclosure Date: March 21, 2019 (last updated April 11, 2024)
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.
0
Attacker Value
Unknown

CVE-2018-7241

Disclosure Date: April 18, 2018 (last updated April 11, 2024)
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
0
Attacker Value
Unknown

CVE-2018-7761

Disclosure Date: April 18, 2018 (last updated April 11, 2024)
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
0
Attacker Value
Unknown

CVE-2018-7760

Disclosure Date: April 18, 2018 (last updated April 11, 2024)
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
0
Attacker Value
Unknown

CVE-2018-7759

Disclosure Date: April 18, 2018 (last updated April 11, 2024)
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.
0
Attacker Value
Unknown

CVE-2018-7762

Disclosure Date: April 18, 2018 (last updated April 11, 2024)
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
0
Attacker Value
Unknown

CVE-2018-7242

Disclosure Date: April 18, 2018 (last updated April 11, 2024)
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.
0
Attacker Value
Unknown

CVE-2017-6017

Disclosure Date: June 30, 2017 (last updated April 11, 2024)
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
0