Show filters
187 Total Results
Displaying 181-187 of 187
Sort by:
Attacker Value
Unknown

CVE-2016-8370

Disclosure Date: February 13, 2017 (last updated November 26, 2024)
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
Attacker Value
Unknown

CVE-2015-3938

Disclosure Date: October 06, 2015 (last updated October 05, 2023)
The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service (device outage) via a long parameter.
0
Attacker Value
Unknown

CVE-2014-7486

Disclosure Date: October 20, 2014 (last updated October 05, 2023)
The Mitsubishi Road Assist (aka com.agero.mitsubishi) application 1.0 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
0
Attacker Value
Unknown

CVE-2013-2817

Disclosure Date: February 24, 2014 (last updated October 05, 2023)
An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click.
0
Attacker Value
Unknown

CVE-2013-3075

Disclosure Date: April 19, 2013 (last updated October 05, 2023)
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
0
Attacker Value
Unknown

CVE-2011-5163

Disclosure Date: September 15, 2012 (last updated October 05, 2023)
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
0
Attacker Value
Unknown

CVE-2008-1546

Disclosure Date: March 28, 2008 (last updated October 04, 2023)
servlet/MIMEReceiveServlet in the web controller for Mitsubishi Electric GB-50 and GB-50A air-conditioning control systems allows remote attackers to cause a denial of service (air-conditioning outage) via an XML document containing a setRequest command.
0