Show filters
19 Total Results
Displaying 11-19 of 19
Sort by:
Attacker Value
Unknown

CVE-2020-29059

Disclosure Date: November 24, 2020 (last updated February 22, 2025)
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.
Attacker Value
Unknown

CVE-2020-29063

Disclosure Date: November 24, 2020 (last updated February 22, 2025)
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. A custom encryption algorithm is used to store encrypted passwords. This algorithm will XOR the password with the hardcoded *j7a(L#yZ98sSd5HfSgGjMj8;Ss;d)(*&^#@$a2s0i3g value.
Attacker Value
Unknown

CVE-2020-29055

Disclosure Date: November 24, 2020 (last updated February 22, 2025)
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. By default, the appliance can be managed remotely only with HTTP, telnet, and SNMP. It doesn't support SSL/TLS for HTTP or SSH. An attacker can intercept passwords sent in cleartext and conduct man-in-the-middle attacks on the management of the appliance.
Attacker Value
Unknown

CVE-2020-29058

Disclosure Date: November 24, 2020 (last updated February 22, 2025)
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can discover cleartext web-server credentials via certain /opt/lighttpd/web/cgi/ requests.
Attacker Value
Unknown

CVE-2020-29056

Disclosure Date: November 24, 2020 (last updated February 22, 2025)
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. One can escape from a shell and acquire root privileges by leveraging the TFTP download configuration.
Attacker Value
Unknown

CVE-2020-29060

Disclosure Date: November 24, 2020 (last updated February 22, 2025)
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account.
Attacker Value
Unknown

CVE-2020-29061

Disclosure Date: November 24, 2020 (last updated February 22, 2025)
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default root126 password for the root account.
Attacker Value
Unknown

CVE-2018-20512

Disclosure Date: January 03, 2019 (last updated November 27, 2024)
EPON CPE-WiFi devices 2.0.4-X000 are vulnerable to escalation of privileges by sending cooLogin=1, cooUser=admin, and timestamp=-1 cookies.
0
Attacker Value
Unknown

CVE-2005-2487

Disclosure Date: August 07, 2005 (last updated February 22, 2025)
Unknown vulnerability in Sun McData switches and directors 4300, 4500, 6064, and 6140 before E/OS 6.0.0 may allow attackers to cause a denial of service (connectivity and array access loss) via a network broadcast storm.
0