CVE-2017-9855

Disclosure Date: August 05, 2017 (last updated November 08, 2023)
An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
0
Attacker Value
Unknown

CVE-2017-9863

Disclosure Date: August 05, 2017 (last updated November 08, 2023)
An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cross-site request forgery can be used to change settings in the inverters (for example, issuing a POST request to change the user password). All Sunny Explorer settings available to the authenticated user are also available to the attacker. (In some cases, this also includes changing settings that the user has no access to.) This may result in complete compromise of the device. NOTE: the vendor reports that exploitation is unlikely because Sunny Explorer is used only rarely. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected