Show filters
247 Total Results
Displaying 11-20 of 247
Sort by:
Attacker Value
Unknown
CVE-2023-30755
Disclosure Date: September 10, 2024 (last updated September 10, 2024)
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources.
This could allow a remote attacker with elevated privileges to cause a denial of service c…
0
Attacker Value
Unknown
CVE-2023-28827
Disclosure Date: September 10, 2024 (last updated September 10, 2024)
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers.
This could allow a remote attacker to cause a denial of service condition in t…
0
Attacker Value
Unknown
CVE-2024-5000
Disclosure Date: June 04, 2024 (last updated June 04, 2024)
An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.
0
Attacker Value
Unknown
CVE-2023-5751
Disclosure Date: June 04, 2024 (last updated January 05, 2025)
A local attacker with low privileges can read and modify any users files and cause a DoS in the working directory of the affected products due to exposure of resource to wrong sphere.
0
Attacker Value
Unknown
CVE-2024-4511
Disclosure Date: May 06, 2024 (last updated May 06, 2024)
A vulnerability classified as critical has been found in Shanghai Sunfull Automation BACnet Server HMI1002-ARM 2.0.4. This affects an unknown part of the component Message Handler. The manipulation leads to buffer overflow. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263115. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
0
Attacker Value
Unknown
CVE-2024-25138
Disclosure Date: March 26, 2024 (last updated April 02, 2024)
In AutomationDirect C-MORE EA9 HMI,
credentials used by the platform are stored as plain text on the device.
0
Attacker Value
Unknown
CVE-2024-25137
Disclosure Date: March 26, 2024 (last updated April 02, 2024)
In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which may lead to a stack overflow. The result of this stack-based buffer overflow can lead to denial-of-service conditions.
0
Attacker Value
Unknown
CVE-2024-25136
Disclosure Date: March 26, 2024 (last updated April 02, 2024)
There is a function in AutomationDirect C-MORE EA9 HMI that allows an attacker to send a relative path in the URL without proper sanitizing of the content.
0
Attacker Value
Unknown
CVE-2023-46285
Disclosure Date: December 12, 2023 (last updated October 08, 2024)
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
0
Attacker Value
Unknown
CVE-2023-46284
Disclosure Date: December 12, 2023 (last updated October 08, 2024)
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
0