Show filters
20 Total Results
Displaying 1-10 of 20
Sort by:
Attacker Value
Unknown
CVE-2024-50377
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
0
Attacker Value
Unknown
CVE-2024-50376
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.
0
Attacker Value
Unknown
CVE-2024-50375
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
0
Attacker Value
Unknown
CVE-2024-50374
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
0
Attacker Value
Unknown
CVE-2024-50373
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
0
Attacker Value
Unknown
CVE-2024-50372
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
0
Attacker Value
Unknown
CVE-2024-50371
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
0
Attacker Value
Unknown
CVE-2024-50370
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
0
Attacker Value
Unknown
CVE-2024-50369
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
0
Attacker Value
Unknown
CVE-2024-50368
Disclosure Date: November 26, 2024 (last updated January 05, 2025)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
0