Unknown

CVE-2024-41927

Disclosure Date: September 04, 2024 (last updated September 20, 2024)
Cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a specific command to PLC's serial communication port, user credentials may be obtained. As a result, the program of the PLC may be obtained, and the PLC may be manipulated.
Attacker Value
Unknown

CVE-2024-45620

Disclosure Date: September 03, 2024 (last updated September 20, 2024)
A vulnerability was found in the pkcs15-init tool in OpenSC. An attacker could use a crafted USB Device or Smart Card, which would present the system with a specially crafted response to APDUs. When buffers are partially filled with data, initialized parts of the buffer can be incorrectly accessed.
Attacker Value
Unknown

CVE-2024-45619

Disclosure Date: September 03, 2024 (last updated September 24, 2024)
A vulnerability was found in OpenSC, OpenSC tools, PKCS#11 module, minidriver, and CTK. An attacker could use a crafted USB Device or Smart Card, which would present the system with a specially crafted response to APDUs. When buffers are partially filled with data, initialized parts of the buffer can be incorrectly accessed.
Attacker Value
Unknown

CVE-2024-45618

Disclosure Date: September 03, 2024 (last updated September 14, 2024)
A vulnerability was found in pkcs15-init in OpenSC. An attacker could use a crafted USB Device or Smart Card, which would present the system with a specially crafted response to APDUs. Insufficient or missing checking of return values of functions leads to unexpected work with variables that have not been initialized.
Attacker Value
Unknown

CVE-2024-45617

Disclosure Date: September 03, 2024 (last updated September 14, 2024)
A vulnerability was found in OpenSC, OpenSC tools, PKCS#11 module, minidriver, and CTK. An attacker could use a crafted USB Device or Smart Card, which would present the system with a specially crafted response to APDUs. Insufficient or missing checking of return values of functions leads to unexpected work with variables that have not been initialized.
Attacker Value
Unknown

CVE-2024-45616

Disclosure Date: September 03, 2024 (last updated September 14, 2024)
A vulnerability was found in OpenSC, OpenSC tools, PKCS#11 module, minidriver, and CTK. An attacker could use a crafted USB Device or Smart Card, which would present the system with a specially crafted response to APDUs. The following problems were caused by insufficient control of the response APDU buffer and its length when communicating with the card.
Attacker Value
Unknown

CVE-2024-45615

Disclosure Date: September 03, 2024 (last updated September 14, 2024)
A vulnerability was found in OpenSC, OpenSC tools, PKCS#11 module, minidriver, and CTK. The problem is missing initialization of variables expected to be initialized (as arguments to other functions, etc.).
Attacker Value
Unknown

CVE-2024-45678

Disclosure Date: September 03, 2024 (last updated September 13, 2024)
Yubico YubiKey 5 Series devices with firmware before 5.7.0 and YubiHSM 2 devices with firmware before 2.4.0 allow an ECDSA secret-key extraction attack (that requires physical access and expensive equipment) in which an electromagnetic side channel is present because of a non-constant-time modular inversion for the Extended Euclidean Algorithm, aka the EUCLEAK issue. Other uses of an Infineon cryptographic library may also be affected.
Attacker Value
Unknown

CVE-2024-33016

Disclosure Date: September 02, 2024 (last updated September 03, 2024)
memory corruption when an invalid firehose patch command is invoked.
Attacker Value
Unknown

CVE-2024-35118

Disclosure Date: August 29, 2024 (last updated September 20, 2024)