Show filters
818 Total Results
Displaying 221-230 of 818
Sort by:
Attacker Value
Unknown

CVE-2022-42899

Disclosure Date: October 13, 2022 (last updated February 24, 2025)
Bentley MicroStation and MicroStation-based applications may be affected by out-of-bounds read and stack overflow issues when opening crafted SKP files. Exploiting these issues could lead to information disclosure and code execution. The fixed versions are 10.17.01.58* for MicroStation and 10.17.01.19* for Bentley View.
Attacker Value
Unknown

CVE-2022-3245

Disclosure Date: September 20, 2022 (last updated February 24, 2025)
HTML injection attack is closely related to Cross-site Scripting (XSS). HTML injection uses HTML to deface the page. XSS, as the name implies, injects JavaScript into the page. Both attacks exploit insufficient validation of user input.
Attacker Value
Unknown

CVE-2022-3242

Disclosure Date: September 20, 2022 (last updated February 24, 2025)
Code Injection in GitHub repository microweber/microweber prior to 1.3.2.
Attacker Value
Unknown

CVE-2022-34110

Disclosure Date: September 12, 2022 (last updated October 08, 2023)
An issue in Micro-Star International MSI Feature Navigator v1.0.1808.0901 allows attackers to download arbitrary files regardless of file type or size.
Attacker Value
Unknown

CVE-2022-34109

Disclosure Date: September 12, 2022 (last updated October 08, 2023)
An issue in Micro-Star International MSI Feature Navigator v1.0.1808.0901 allows attackers to write arbitrary files to the directory \PromoPhoto\, regardless of file type or size.
Attacker Value
Unknown

CVE-2022-34108

Disclosure Date: September 12, 2022 (last updated October 08, 2023)
An issue in the Feature Navigator of Micro-Star International MSI Feature Nagivator v1.0.1808.0901 allows attackers to cause a Denial of Service (DoS) via a crafted image or video file.
Attacker Value
Unknown

CVE-2022-2277

Disclosure Date: September 06, 2022 (last updated February 24, 2025)
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
Attacker Value
Unknown

CVE-2022-29490

Disclosure Date: September 06, 2022 (last updated February 24, 2025)
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
Attacker Value
Unknown

CVE-2022-29922

Disclosure Date: September 06, 2022 (last updated February 24, 2025)
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys6…
Attacker Value
Unknown

CVE-2022-29492

Disclosure Date: September 06, 2022 (last updated February 24, 2025)
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada…